BISPECTRAL INDEX MONITORING IN ANESTHESIOLOGY: A NARRATIVE REVIEW

Authors

DOI:

https://doi.org/10.31435/ijitss.3(51).2026.6113

Keywords:

Bispectral Index (BIS), Anesthesia Monitoring, Depth of Sedation, Electroencephalography (EEG), Intraoperative Awareness, Sedation Assessment

Abstract

Introduction: Accurate assessment of anesthetic depth is crucial for patient safety and optimal drug administration. The Bispectral Index (BIS), an EEG-derived quantitative measure, has become widely used to monitor hypnosis in various anesthetic contexts. Despite its popularity, BIS interpretation faces challenges from physiological variability, patient-specific factors, and technical limitations.

Methods: This narrative review synthesized evidence from PubMed searches restricted to the last 10 years, including randomized controlled trials, systematic reviews, and observational studies evaluating BIS monitoring. Articles covering technical aspects, clinical applications, patient-group specific performance, limitations, physiological correlations, and outcomes were prioritized. Thematic synthesis was used rather than meta-analysis.

Results: BIS effectively guides anesthetic titration, reducing intraoperative awareness and anesthetic consumption across adult and pediatric populations. Challenges include variability due to age-related EEG differences, EMG interference, and anesthetic agent-specific EEG effects. Complementary indices like response entropy and machine learning models enhance BIS reliability. Closed-loop anesthesia delivery guided by BIS shows promise in improving administration precision. Optimal BIS ranges support improved hemodynamics and reduce postoperative morbidity and mortality risks.

Conclusions: BIS remains a valuable clinical tool for monitoring anesthetic depth when interpreted with awareness of its limitations. Advances in AI, multimodal monitoring, and personalization will likely improve BIS utility. Continued research is essential to optimize anesthesia management and patient outcomes through enhanced brain monitoring technologies.

References

Liang, T., Wu, F., Wang, B., & Mu, F. (2021). PRISMA: Accuracy of response entropy and bispectral index to predict the transition of consciousness during sevoflurane anesthesia: A systematic review and meta-analysis. Medicine, 100(17), e25718. https://doi.org/10.1097/MD.0000000000025718

Epstein, R. H., Maga, J. M., Mahla, M. E., et al. (2018). Prevalence of discordant elevations of state entropy and bispectral index in patients at amnestic sevoflurane concentrations: A historical cohort study. Can J Anesth/J Can Anesth, 65, 512–521. https://doi.org/10.1007/s12630-018-1085-3

Ganesh, A., & Watcha, M. F. (2004). Bispectral index monitoring in pediatric anesthesia. Current Opinion in Anaesthesiology, 17(3), 229–234. https://doi.org/10.1097/00001503-200406000-00006

Lewis, S. R., Pritchard, M. W., Fawcett, L. J., & Punjasawadwong, Y. (2019). Bispectral index for improving intraoperative awareness and early postoperative recovery in adults. The Cochrane Database of Systematic Reviews, 9(9), CD003843. https://doi.org/10.1002/14651858.CD003843.pub4

Kim, J.-K., Kim, D.-K., & Lee, M.-J. (2014). Relationship of bispectral index to minimum alveolar concentration during isoflurane, sevoflurane or desflurane anaesthesia. Journal of International Medical Research, 42(1), 130–137. https://doi.org/10.1177/0300060513505525

Punjasawadwong, Y., Phongchiewboon, A., & Bunchungmongkol, N. (2014). Bispectral index for improving anaesthetic delivery and postoperative recovery. The Cochrane Database of Systematic Reviews, 2014(6), CD003843. https://doi.org/10.1002/14651858.CD003843.pub3

de Oliveira, D. A. C., Dos Santos Monteiro, J., de Macêdo, N. R., Tavares Costa Santos, A. H., & Rosa Neves, S. M. (2025). Bispectral index-guided anesthesia in children: A systematic review and meta-analysis. Anaesthesia, Critical Care & Pain Medicine, 44(6), 101607. https://doi.org/10.1016/j.accpm.2025.101607

Jin, S., Baik, H. J., Cho, S., Chung, R. K., Kong, K. A., & Kim, Y. J. (2021). The influence of neuromuscular blockade on phase lag entropy and bispectral index: A randomized, controlled trial. PLOS ONE, 16(9), e0257467. https://doi.org/10.1371/journal.pone.0257467

Xin, Y., Ma, L., Xie, T., Liang, Y., Ma, M., Chu, T., Liu, C., & Xu, A. (2023). Comparative analysis of the effect of electromyogram to bispectral index and 95% spectral edge frequency under remimazolam and propofol anesthesia: A prospective, randomized, controlled clinical trial. Frontiers in Medicine, 10, 1128030. https://doi.org/10.3389/fmed.2023.1128030

Hua, L., Du, B., Zuo, Y., Liu, H., & Zhang, J. (2024). Clinical evaluation of bispectral index-guided closed-loop infusion of propofol for preschool children: A multi-center randomized controlled study. Pediatric Investigation, 8(4), 271–277. https://doi.org/10.1002/ped4.12449

Oliveira, C. R., Bernardo, W. M., & Nunes, V. M. (2017). Benefit of general anesthesia monitored by bispectral index compared with monitoring guided only by clinical parameters: Systematic review and meta-analysis. Brazilian Journal of Anesthesiology (Elsevier), 67(1), 72–84. https://doi.org/10.1016/j.bjane.2015.09.001

Lim, T. W., Choi, Y. H., Kim, J. Y., et al. (2020). Efficacy of the bispectral index and Observer’s Assessment of Alertness/Sedation Scale in monitoring sedation during spinal anesthesia: A randomized clinical trial. Journal of International Medical Research, 48(4). https://doi.org/10.1177/0300060519893165

Zhou, C., Huang, X., Zhuo, Z., et al. (2024). Effect of different anesthesia depths on perioperative heart rate variability and hemodynamics in middle-aged and elderly patients undergoing general anesthesia. BMC Anesthesiol, 24, 312. https://doi.org/10.1186/s12871-024-02700-9

Bickel, A., Gavrilov, A., Ivry, S., Maimon, N. B., Molcho, L., & Intrator, N. (2020). Reduced neural activity during volatile anesthesia compared to TIVA: Evidence from a novel EEG signal processing analysis. arXiv. https://doi.org/10.48550/arXiv.2009.14264

Jang, Y. E., Kim, E. H., Lee, J. H., Kim, J. T., & Kim, H. S. (2022). Usefulness of bispectral index and patient state index during sevoflurane anesthesia in children: A prospective observational study. Medicine, 101(30), e29925. https://doi.org/10.1097/MD.0000000000029925

Cheriyan, T., Bai, K., Bayyapureddy, S., Dua, A., Singh, P., Sun, Z., Patel, C., & Kumar, V. (2024). Effect of bispectral index on intra-operative awareness: A meta-analysis of randomized controlled studies. Saudi Journal of Anaesthesia, 18(3), 360–370. https://doi.org/10.4103/sja.sja_74_24

Yoon, S., Yoo, S., Hur, M., et al. (2020). The cumulative duration of bispectral index less than 40 concurrent with hypotension is associated with 90-day postoperative mortality: A retrospective study. BMC Anesthesiol, 20, 200. https://doi.org/10.1186/s12871-020-01122-7

McGuigan, S., Scott, D. A., Evered, L., Silbert, B., & Liley, D. T. J. (2023). Performance of the bispectral index and electroencephalograph derived parameters of anesthetic depth during emergence from xenon and sevoflurane anesthesia. Journal of Clinical Monitoring and Computing, 37(1), 71–81. https://doi.org/10.1007/s10877-022-00860-y

Stewart, J. A., Särkelä, M. O. K., Wennervirta, J., et al. (2022). Novel insights on association and reactivity of Bispectral Index, frontal electromyogram, and autonomic responses in nociception-sedation monitoring of critical care patients. BMC Anesthesiol, 22, 353. https://doi.org/10.1186/s12871-022-01864-6

Qi, Y., Wang, X., Cui, Y., et al. (2026). AnesNet: A versatile deep convolutional framework for predicting depth of anesthesia using BIS and multimodal intraoperative signals. BMC Anesthesiol, 26, 198. https://doi.org/10.1186/s12871-026-03710-5

Zhao, Tym., Chen, D., Xu, Zx., et al. (2023). Comparison of bispectral index and patient state index as measures of sedation depth during surgeries using remimazolam tosilate. BMC Anesthesiol, 23, 208. https://doi.org/10.1186/s12871-023-02172-3

Gao, Ww., He, Yh., Liu, L., et al. (2018). BIS monitoring on intraoperative awareness: A meta-analysis. CURR MED SCI, 38, 349–353. https://doi.org/10.1007/s11596-018-1886-1

Downloads

Published

2026-09-16

How to Cite

Piotrowski, P., Łagosz, H., Wites, P., Wites, K., Włodarczyk, A., Jabłońska, A., Pyzik, M., Ziółkowska, K., Markusiewicz, K., & Bahyrycz, P. (2026). BISPECTRAL INDEX MONITORING IN ANESTHESIOLOGY: A NARRATIVE REVIEW. International Journal of Innovative Technologies in Social Science, 3(3(51). https://doi.org/10.31435/ijitss.3(51).2026.6113

Most read articles by the same author(s)